site stats

Synthesis femur nail system

WebSynthes IM Femoral Nail Insertion Technique. - See: ( Synthes Product Menu) - Reaming and Nailing Maneuver. - Intramedullary Nailing. - Miss A Nail Technique. - Spiral Blade. - … WebThe pediatric nailing platform from OrthoPediatrics is a comprehensive femoral nail system for both trauma and deformity in pediatric patients. See sizes and details.

T2 Femur A/R Stryker

WebThe AUTOBAHN® Antegrade/Retrograde Femoral Nailing System is a comprehensive system of implants and instruments for the treatment of femoral shaft fractures as well as fractures in the proximal and distal third regions of the femur. The system offers reconstruction screw solutions that target the femoral neck for the antegrade approach … WebDistal Radius Intramedullary Nail (DRIM-Nail) for the fixation of extraarticular fractures Automated Deformity Analysis and Osteotomy Planning Tool in the Coronal Plane Cannulated Screw System CSS CONDUIT™ Lumbar Cages─Part of the CONDUIT™ Interbody Platform UNIUM™ Small Bone and Trauma Power Tool fergus hickey points table https://gr2eng.com

SYNTHES TFN TECHNIQUE MANUAL Pdf Download

WebAug 20, 2024 · The Arthrex Femoral Nail System is targeted for use in intramedullary fixation of fractures of the femur. Consisting of antegrade and retrograde femoral opti... WebThe new 3.5/4.5 Variable Angle LCP® Periprosthetic Proximal Femur Plating System was developed for treatment of Vancouver types A and B fractures. It is offered in stainless steel. The modular system consists of anatomically pre-shaped plates with variable angle locking screw technology. delete flying blue account

Synthes Tens Nails - Cambridge Orthopaedics

Category:AUTOBAHN® Femoral Nailing System Globus Medical

Tags:Synthesis femur nail system

Synthesis femur nail system

Retrograde nailing for Fracture proximal to the femoral component

http://www.cambridgeorthopaedics.com/easytrauma/classification/surgtech/ao/manuals/Synthes%20TENS%20nails.pdf WebAn intramedullary rod, also known as an intramedullary nail (IM nail) or inter-locking nail or Küntscher nail (without proximal or distal fixation), is a metal rod forced into the medullary cavity of a bone.IM nails have long been used to treat fractures of long bones of the body. Gerhard Küntscher is credited with the first use of this device in 1939, during World War II, …

Synthesis femur nail system

Did you know?

WebDec 18, 2024 · Intramedullary nail is the preferred synthesis because it allows a reduction of the time of surgery, a stable synthesis and an early patient mobilization [ 14 ]. In particular, these considerations are valid for more stable PFs, classified with AO/OTA [ 15] pattern 31-A1 (pertrochanteric simple) and 31-A2 (pertrochanteric multifragmentary). http://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/Product%20Support%20Material/legacy_Synthes_PDF/DSEM-TRM-0714-0116-3_LR.pdf

Webproximal nail end determines the definitive angle of insertion for the Guide Wire. Insert the Guide Wire for approx. 8–10 cm and check the posi-tion under the image intensifier in AP and lateral views. 7 Open medullary canal – cutter Instruments Guide Wire 3.2 mm 357.399 Cutter for Tibial Nails, 12.0 mm, length 350 mm 03.010.008 WebCare should be taken with the approach for retrograde nailing as several anatomical structures are at risk. The most important potential hazard is damage to the anterior cruciate ligament. In addition, cartilage from the weight bearing zone may be damaged if a non-anatomic approach is selected. A non-anatomic approach can also lead to a failure ...

Websynthes.vo.llnwd.net WebDescription. Titanium Cannulated Adolescent Lateral Entry Femoral Nail The Titanium Cannulated Adolescent Lateral Entry Femoral Nail-EX (ALFN) is part of the DePuy Synthes …

WebHelps Restore Natural Anatomic Shape to Fractured Long Bones. The Zimmer ® Natural Nail ® Antegrade helps restore the natural anatomic shape of the femur when treating femoral shaft fractures. This antegrade intramedullary nail system is available in a variety of diameters and lengths with varying anterior bows to accommodate varying patient anatomy.

WebT2 Femur A/R Nailing System. The T2 Femoral Nailing System offers a universal left and right nail in addition to an antegrade or retrograde approach that may reduce inventory. … fergus horseWebThe DePuy Synthes Advanced Nail System provides stability solutions to empower you and your patients to do more. With a growing fragility fracture population 1-3 , the Advanced … fergus humoristeWebThe T2 Alpha Femur Antegrade GT / PF Nailing System is intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved. The indications for use of these internal fixation devices include: - Fixation of subtrochanteric, intertrochanteric, comminuted proximal femoral shaft fractures - … delete focus time outlook calendarWebSynthes Tens Nails - Cambridge Orthopaedics delete flow run historyWebMay 1, 2024 · All nails broke at the proximal screw aperture, with 1 nail additionally breaking at the distal aperture. Of 8 patients treated with a second TFNA implant for nail breakage, 3 (38%) returned with ... delete flutter from windowsWebThe Femoral Nail System is used for intramedullary fixation for fractures of the femur. The system contains unique screw configurations for both antegrade and retrograde nailing. This combination of versatility and diversity offers surgeons comprehensive solutions for managing femoral fractures. Antegrade Nail Features: delete folder but not contentsWebJan 1, 2024 · synthesis, a nd pat hologic f racture s were excluded from the . ... (123 using Depuy Synthes Trochanteric Fixation Nail proximal femoral nailing system (TFN) with static locking; 65 TFN with ... delete folder powershell sharepoint